Breaking Capacity: | 10 KA | Poles Available: | 1P, 2P, 3P, 3P+N, 4P |
---|---|---|---|
Ampere: | 6A,10A,16A,20A,25A,32A,40A,50A,63A | Residual Protection: | Yes |
Overload Protection: | Yes | Type: | Mini Circuit Breaker |
High Light: | compact circuit breaker,micro circuit breaker |
3 Pole 10000A Earth Leakage Mini Circuit Breaker Overload Protection
The ELCB is applied to the circuit of AC 50Hz with rated voltage up to 400V, rated current up to 50A, power supply neutral point earthing. It's mainly used to protect person from getting an electric shock and protect the building′s circuit devices from over current, it also can protect the earthing fault.
The ELCB is according with IEC61009-1:1991, GB16917.1-1997 standard.
Specifications:
Technology Specification & Electrical Specification | |
Electric standard | IEC61009; GB 16917.0 |
Trip time | Non-time delay; Minimal 10ms time delay |
Rated voltage | 230V; 50HZ 230V/400V |
Rated surplus operating current | 10; 30; 100; 300mA |
Selection grade | 3 |
Rated braking capacity | 10kA |
Rated current | 6-63A |
Tripping character | B, C, D characteristic curve |
Maximum connected fuse | 100A gL(> 10kA) |
Environment capability | According to the IEC 1008 standard |
Case protection grade | IP40 after installation |
Electric life | Not less than 4000 times of breaking and closing |
Mechanical life | Not less than 2000 times of breaking and closing |
Mechanical Parameter | |
Installation mode | Installation at the DIN guide rail of 35mm |
Terminal block capacity | Generatrix thickness 0.8-2mm |
Normal working condition and installation condition:
1. The maximum ambient temperature should be -5°C≤T≤40°C,average temperature should be ≤35°C
at 24h
2.The altitude of installation place should not exceed 2000m.
3. The relative humidity should not exceed 50% at 40°C, it permits higher relative humidity when at a higher temperature, the average maximum relative humidity should not exceed 90% at maximum humidity month, and this month′s average minimum temperature does not exceed +25°C, and should take consideration of the condensation on the product′s surface for temperature change.
4. Pollution grade: 2
5. Installation type: 1,2
6. The external magnetic field of installation place should not exceed 5 times of earth magnetic field.
7. The mini circuit breaker is installed by standard mounting rail.
8. The mini circuit breaker is upright installation, knob upwards is switch on position
9. The installation place should be without obviously impact and libration.
Tripping Curve:
Contact Person: Allen
IP66 IP67 32 Amp Rotary Isolator Switch Disconnector For Solar PV System
Weatherproof 100 Amp Disconnect Switch with 1NO+1NC For Rotary Isolating
Waterproof IP65 Rotary Isolator Switch / 2 Pole 3 Pole Disconnect Switch
Blue IP44 Industrial Power Socket Pin And Sleeve Electrical Connectors
Pin and Sleeve Plug Industrial Power Socket IP44 IP67 Coupler Connector
Mechanical Interlock Industrial Power Switched Sockets , Single / Three Phase
Three Phase Fire-retardant Enclsoure AC Compressor Contactor And Relays 180A
Electrical Switch Over Switch AC Contactor Magnetic 9A 12A 18A 22A
GMC 4P Mini Mechanical Interlocking Home AC Contactor Gmc 9mr 9A 3 Phase Contactor
9A 12A 18A 22A Single Phase DOL Starter AC Contactor Definite Purpose